Controlling the frequency spectrum ( bandwidth) of a RF pulse (via tailoring) while imposing a magnetic field gradient on spins, such that only a desired region will have an appropriate resonant frequency to be excited.
Originally used to excite all but a desired region; now often used to select only a desired region, such as a plane, for excitation. Used without simultaneous magnetic field gradients, tailored RF pulses can be used to selectively excite a particular spectral line or group of lines. RF and gradient pulse combinations can be designed to select both spatial regions and spectral frequencies. | |  | | • View the DATABASE results for 'Selective Excitation' (17).
| | | | |
|  | |  |  |  |
| |
|
A generally smooth background curve, only the data above the baseline/background will be included in the calculation. Either the integrals or peak heights of the resonance spectral lines in the spectrum are measured. For BOLD imaging it is a non-activated image, in contrast to an activated image. | |  | | • View the DATABASE results for 'Baseline' (9).
| | | | Further Reading: | News & More:
|
|
| |
|  |  | Searchterm 'Spectra' was also found in the following services: | | | | |
|  |  |
| |
|
(MR mammography) Magnetic resonance imaging of the breast is particularly useful in evaluation of newly diagnosed breast cancer, in women whose breast tissue is mammographically very dense and for screening in women with a high lifetime risk of breast cancer because of their family history or genetic disposition.
Breast MRI can be performed on all standard whole body magnets at a field strength of 0.5 T - 1.5 Tesla. Powerful gradient strengths over 15 mT/m will help to improve the balance between spatial resolution, scanning speed, and volume coverage. The use of a dedicated bilateral breast coil is obligatory.
Malignant lesions release angiogenic factors that increase local vessel density and vessel permeability. Breast cancer is detectable due to the strong enhancement in dynamic breast imaging that peaks early (about 1-2 min.) after contrast medium injection. If breast cancer is suspected, a breast biopsy may be necessary to secure the diagnosis. See also Magnetic Resonance Imaging MRI, Biopsy and MR Guided Interventions.
Requirements in breast MRI procedures:
•
Both breasts must be measured without gaps.
•
For the best possible detection of enhancement fat signal should be eliminated either by image subtraction or by
spectrally selective fat saturation.
•
Thin slices are necessary to assure absence of partial
volume effects.
•
Imaging should be performed with a spatial
resolution in plane less than 1 mm.
For Ultrasound Imaging (USI) see Breast Ultrasound at Medical-Ultrasound-Imaging.com.
See also the related poll result: ' MRI will have replaced 50% of x-ray exams by' | | | | | | | | | | | • View the DATABASE results for 'Breast MRI' (13).
| | | • View the NEWS results for 'Breast MRI' (41).
| | | | Further Reading: | Basics:
|
|
News & More:
|  |
Technology advances in breast cancer screenings lead to early diagnosis Friday, 6 October 2023 by ksltv.com |  |  |
Are synthetic contrast-enhanced breast MRI images as good as the real thing? Friday, 18 November 2022 by healthimaging.com |  |  |
Abbreviated breast MRI protocols not as cost-effective as promised, new study shows Wednesday, 20 July 2022 by healthimaging.com |  |  |
Deep learning poised to improve breast cancer imaging Thursday, 24 February 2022 by www.eurekalert.org |  |  |
Pre-Operative Breast MRI Can Help Identify Patients Likely to Experience Nipple-Sparing Mastectomy Risks Wednesday, 7 April 2021 by www.diagnosticimaging.com |  |  |
Breast cancer screening recalls: simple MRI measurement could avoid 30% of biopsies Monday, 1 March 2021 by www.eurekalert.org |  |  |
A Comparison of Methods for High-Spatial-Resolution Diffusion-weighted Imaging in Breast MRI Tuesday, 25 August 2020 by pubs.rsna.org |  |  |
Pre-Operative Breast MRI Diagnoses More Cancers in Women with DCIS Thursday, 9 July 2020 by www.diagnosticimaging.com |  |  |
Breast MRI and tumour biology predict axillary lymph node response to neoadjuvant chemotherapy for breast cancer Thursday, 26 December 2019 by cancerimagingjournal.biomedcentral.com |  |  |
Breast MRI Coding Gets an Overhaul in 2019 Wednesday, 9 January 2019 by www.aapc.com |  |  |
How accurate are volumetric software programs when compared to breast MRI? Thursday, 27 July 2017 by www.radiologybusiness.com |  |  |
Additional Breast Cancer Tumors Found on MRI After Mammography May Be Larger, More Aggressive Wednesday, 9 December 2015 by www.oncologynurseadvisor.com |  |  |
Preoperative MRI May Overdiagnose Contralateral Breast Cancer Wednesday, 2 December 2015 by www.cancertherapyadvisor.com |  |  |
BI-RADS and breast MRI useful in predicting malignancy Wednesday, 30 May 2012 by www.oncologynurseadvisor.com |
|
| |
|  |  | Searchterm 'Spectra' was also found in the following service: | | | | |
|  |  |
| |
|
MRI computer can be divided into central processing unit (CPU), consisting of instruction, interpretation and arithmetic unit plus fast access memory, and peripheral devices such as bulk data storage and input and output devices (including, via the interface, the spectrometer).
The computer controls the RF pulses and gradients necessary to acquire data, and process the data to produce spectra or images. (Devices such as the spectrometer may themselves incorporate small computers.)
See also Digital to Analog Converter, Analog to Digital Converter, Transformer, Pulse Programmer, Array Processor, Detector.
See also the related poll result: ' Most outages of your scanning system are caused by failure of' | |  | | • View the DATABASE results for 'Computer' (37).