Plural of spectrum. Spectra are components of the MR signal according to frequencies. Spectroscopy uses NMR spectral components to identify the metabolites, e.g. of the brain. | | | | | • Share the entry 'Spectra': | | | | | | | | |
| | | Searchterm 'Spectra' was also found in the following service: | | | | |
| | |
| |
|
The mapping of a CSI spectral matrix to an anatomical image. It shows the regional changes in metabolites as superimposed contours. | | | | | |
| | | | | |
| |
|
A spectral line is a particular distinct frequency or narrow band of a frequency set. The resonance of this frequency occurs corresponding to a particular chemical shift. Theoretically, the frequency of a pure sine wave displays sharp spectral lines at the point of Larmor frequency. In reality, the spectral lines spread into a blurred peak, caused by field inhomogeneities and spin-spin effect. | | | | • View the DATABASE results for 'Spectral Line' (21).
| | | | |
| | | Searchterm 'Spectra' was also found in the following services: | | | | |
| | |
| |
|
The overall width in hertz needed to observe a particular NMR spectrum. This width is generally set using the Nyquist limit; namely, that the temporal sampling rate must be equal to twice the maximum spread in frequencies. | | | | | |
| | | Searchterm 'Spectra' was also found in the following service: | | | | |
| | |
| |
|
From Siemens Medical Systems;
Received FDA clearance in 2012.
The MAGNETOM Spectra is a cost-optimized high field MRI system with Tim 4G and Dot technologies. The system consumes less energy compared to other 3 Tesla scanners. The magnet-cooling helium is contained in a closed loop, which prevents the gas from escaping and reduces the need for refills. TimTX includes innovative techniques in the radio frequency excitation hardware as well as new application and processing features enabling uniform RF distribution in all body regions.
Device Information and Specification
CLINICAL APPLICATION
Whole Body
Head, spine, torso/ body coil, neurovascular, neck and multi-purpose flex coils. Peripheral vascular, breast, shoulder, knee, wrist, foot//ankle, endorectal optional.
Chemical shift imaging, single voxel spectroscopy
DIMENSION H*W*D (gantry included)
173 x 231 x 219 cm
COOLING SYSTEM
Water; single cryogen, 2 stage refrigeration
Passive, active; first order standard, second order optional
POWER REQUIREMENTS
380 / 400 / 420 / 440 / 460 / 480 V, 3-phase + ground; connection value with chiller 100 kvA /without chiller 60 kVA
| | | | | |
| | | | |
| |
| | | |
|
| |