Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'T2 Relaxation' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'T2 Relaxation' found in 1 term [] and 19 definitions []
previous     11 - 15 (of 20)     next
Result Pages : [1]  [2 3 4]
Searchterm 'T2 Relaxation' was also found in the following services: 
spacer
News  (2)  Resources  (1)  Forum  (2)  
 
Driven EquilibriumInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
In fast imaging sequences driven equilibrium sensitizes the sequence to variations in T2. This MRI technique turns transverse magnetization Mxy to the longitudinal axis using a pulse rather than waiting for T1 relaxation.
The first two pulses form a spin echo and, at the peak of the echo, a second 90° pulse returns the magnetization to the z-axis in preparation for a fresh sequence. In the absence of T2 relaxation, then all the magnetization can be returned to the z-axis. Otherwise, T2 signal loss during the sequence will reduce the final z-magnetization.
The advantage of this sequence type is, that both longitudinal and also transverse magnetization are back to equilibrium in a shorter amount of time. Therefore, contrast and signal can be increased while using a shorter TR. This pulse type can be applied to other sequences like FSE, GE or IR.

Sequences with driven equilibrium:
Driven Equilibrium Fast Gradient Recalled acquisition in the steady state - DE FGR,
Driven Equilibrium Fourier Transformation - DEFT,
Driven Equilibrium magnetization preparation - DE prep,
Driven Equilibrium Fast Spin Echo - DE FSE.
 
Images, Movies, Sliders:
 MRI of the Skull Base  Open this link in a new window
    
SlidersSliders Overview

 
spacer
 
• Related Searches:
    • Longitudinal Relaxation
    • Contrast Enhanced Gradient Echo Sequence
    • Driven Equilibrium Magnetization Preparation
    • Transverse Magnetization
    • Fourier Transformation
 
Further Reading:
  Basics:
3D Turbo Spin-Echo Sequence with Motion-Sensitized Driven-Equilibrium Preparation for Detection of Brain Metastases on 3T MR Imaging
Saturday, 3 December 2011   by www.ajnr.org    
  News & More:
Advances in high-field MR imaging of the spine
Wednesday, 5 August 2009   by www.appliedradiology.com    
Comparison of New Methods for Magnetic Resonance Imaging of Articular Cartilage(.pdf)
2002
MRI Resources 
Shielding - Safety Products - Online Books - Contrast Enhanced MRI - Intraoperative MRI - Cochlear Implant
 
Free Induction Decay
 
(FID) A free induction decay curve is generated as excited nuclei relax. The amplitude of the FID signal becomes smaller over time as net magnetization returns to equilibrium. If transverse magnetization of the spins is produced, e.g. by a 90° pulse, a transient MR signal will result that will decay toward zero with a characteristic time constant T2 (or T2*); this decaying signal is the free induction decay.
The signal peaks of the echoes fall onto this T2 decay curve, while at each echo the signals arise and decay with T2*. The typical T2 relaxation times being of the order of 5-200 ms in the human body. The first part of the FID is not observable (named the 'receiver dead time') caused by residual effects of the powerful exciting radio frequency pulse on the electronics of the receiver.
spacer

• View the DATABASE results for 'Free Induction Decay' (8).Open this link in a new window

 
Further Reading:
  Basics:
Free induction decay
   by en.wikipedia.org    
  News & More:
Magnetic resonance imaging
   by www.scholarpedia.org    
MRI Resources 
Absorption and Emission - MRI Accidents - Spectroscopy - - Veterinary MRI - Pregnancy
 
GadoversetamideInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.
 
Short name: Gd-DTPA-BMEA, generic name: Gadoversetamide
A paramagnetic extracellular MRI contrast agent with positive enhancement. When placed in a magnetic field, gadoversetamide decreases T1 and T2 relaxation times in tissues where it accumulates. At the recommended dose, the effect is primarily on T1 relaxation time, and produces an increase in signal intensity (brightness).

See Contrast Agents and OptiMARK™.
spacer

• View the DATABASE results for 'Gadoversetamide' (3).Open this link in a new window


• View the NEWS results for 'Gadoversetamide' (1).Open this link in a new window.
 
Further Reading:
  Basics:
OptiMARK® (gadoversetamide injection)
  News & More:
MAGNETIC RESONANCE IMAGING OF FOCAL LIVER LESIONS(.pdf)
2002
Searchterm 'T2 Relaxation' was also found in the following services: 
spacer
News  (2)  Resources  (1)  Forum  (2)  
 
Inversion Recovery Spin Echo
 
(IRSE) Form of inversion recovery imaging in which the signal is detected as a spin echo. For TE short compared to the T2 relaxation time, there will be only a small effect of T2 differences on image intensities; for longer TE's, the effect of T2 may be significant.
spacer
 
Further Reading:
  Basics:
Magnetic resonance imaging
   by www.scholarpedia.org    
MRI Resources 
General - Research Labs - Fluorescence - MR Guided Interventions - Chemistry - Collections
 
Low Field MRIForum -
related threads
 
Advantages of low field imaging are the small-sized 5 Gauss fringe field and therefore the less static magnetic field exposure for the surrounding area, as well as less contraindications causing lower risks for the MRI safety by implemented metal and magnetic devices and equipment.
Low field systems are sometimes for restricted use, e.g. dedicated extremity scanner or open MRI devices. Open MRI devices equipped with permanent magnets are well-suited for MR guided interventions because these machines combine the lower magnetic fields of this type of magnets and the better patient access of open MRI scanner.
In some cases, the contrast of different tissues is better at lower field strength, depending on their T1 or T2 relaxation times. The disadvantage of the lower signal to noise ratio are a poor resolution and a longer scan time for a good image quality.

See also Claustrophobia, Contraindications and MRI Safety.

See also the related poll result: 'In 2010 your scanner will probably work with a field strength of'
spacer

• View the DATABASE results for 'Low Field MRI' (8).Open this link in a new window


• View the NEWS results for 'Low Field MRI' (5).Open this link in a new window.
 
Further Reading:
  Basics:
Improving portable low-field MRI image quality through image-to-image translation using paired low- and high-field images
Friday, 1 December 2023   by www.nature.com    
  News & More:
Safety of Bedside Portable Low-Field Brain MRI in ECMO Patients Supported on Intra-Aortic Balloon Pump
Friday, 18 November 2022   by www.mdpi.com    
Researchers at the University of Tsukuba develop a portable MRI system specifically for identifying wrist cartilage damage among athletes, providing a convenient means of early detection and treatment of injuries
Tuesday, 26 April 2022   by www.tsukuba.ac.jp    
This bizarre looking helmet can create better brain scans
Friday, 11 February 2022   by www.sciencedaily.com    
A low-cost and shielding-free ultra-low-field brain MRI scanner
Tuesday, 14 December 2021   by www.nature.com    
Portable MRI provides life-saving information to doctors treating strokes
Thursday, 5 August 2021   by news.yale.edu    
Synaptive Evry, an MRI for Any Space, Cleared by FDA
Thursday, 30 April 2020   by www.medgadget.com    
World's First Portable MRI Cleared by FDA
Monday, 17 February 2020   by www.medgadget.com    
Introducing a point-of-care MRI system
Tuesday, 29 October 2019   by healthcare-in-europe.com    
Opportunities in Interventional and Diagnostic Imaging by Using High-performance Low-Field-Strength MRI
Tuesday, 1 October 2019   by pubs.rsna.org    
Portable 'battlefield MRI' comes out of the lab
Thursday, 30 April 2015   by physicsworld.com    
Portable MRI could aid wounded soldiers and children in the third world
Thursday, 23 April 2015   by phys.org    
MRI Resources 
Universities - Spectroscopy - Guidance - Abdominal Imaging - Claustrophobia - Databases
 
previous      11 - 15 (of 20)     next
Result Pages : [1]  [2 3 4]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.