 | Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | | | |
 | Out- side |
| | | | |
|
| | | | |
Result : Searchterm 'Trace Image' found in 1 term [ ] and 1 definition [ ], (+ 14 Boolean[ ] results
| previous 11 - 15 (of 16) nextResult Pages : [1] [2 3 4] |  | | |  |  |  |
| |
|
Liver imaging with gadolinium contrast enhanced MRI is sometimes not sufficient for a reliable diagnosis of liver lesions.
For this reasons, special liver Contrast agents that are targeted to the reticuloendothelial system (RES), have been developed to improve both detection and characterization of liver and spleen lesions. Reticuloendothelial Contrast Agents, as e.g. superparamagnetic iron oxides ( SPIO), are taken up by healthy liver tissue but not tumors.
These RES targeted contrast agents provide a prolonged imaging window and enough time for high spatial resolution or multiple breath hold images. Reticuloendothelial contrast agents have an increased sensitivity for the detection of small liver lesions (e.g., metastases), compared with gadolinium enhanced MRI and spiral CT. At higher field strengths with an increased signal to noise ratio the susceptibility effect with iron oxide particles may be enhanced.
Other new agents ( Gadobenate Dimeglumine, Gadoxetic Acid) have both an initial ex tracellular circulation and a delayed liver-specific uptake. Since a considerable part of these contrast agents is excreted in the bile, functional biliary imaging can diagnose biliary anomalies, postoperative bile leaks, and anastomotic strictures. Other agents, such as liposomes (with encapsulated Gd-DTPA) or DOTA complexes are in different development stages.
See also Hepatobiliary Contrast Agents, Gadolinium Oxide, Superparamagnetic Iron Oxide and Liposomes. | |  | | | |
|  | |  |  |  |
| |
|
Drug Information and Specification T1, Predominantly positive enhancement PHARMACOKINETIC Intravascular, extracellular, renal excretion DOSAGE 0.1-0.3 mmol/kg / 0.2-0.6 mL/kg PREPARATION Finished product INDICATION Neuro/whole body DEVELOPMENT STAGE For sale PRESENTATION Vials of 5, 10, 15, 20 and 100 mL bulk package
Pre-filled syringes of 10, 15 and 20 mL DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information TERRITORY TRADE NAME DEVELOPMENT STAGE DISTRIBUTOR USA, Canada Magnevist® for sale Turkey Magnevist®, Magnograf for sale Australia Magnevist® for sale | |  | | • View the DATABASE results for 'Magnevist®' (7).
| | | | Further Reading: | | Basics:
|
|
News & More:
| |
| |
|  | |  |  |  |
| |
|
Most of the commonly used intrauterine con traceptive devices (IUD) do not move under the influence of the magnetic field, do not heat up during sequences usually applied for pelvic imaging, and do not produce major artifacts in vitro or in vivo.
Thus, patients with either all plastic or copper IUDs can be safely imaged with magnetic resonance imaging ( MRI) machines. | |  | | | |
|  | |  |  |  |
| |
|
Drug Information and Specification T1, Predominantly positive enhancement PHARMACOKINETIC Intravascular, extracellular, renal excretion CONCENTRATION 287 mg/mL,0.5 mol/L DOSAGE 0.1-0.2 mmol/kg / 0.2-0.4 ml/kg PREPARATION Finished product INDICATION Neuro/whole body DEVELOPMENT STAGE For sale PRESENTATION Vials of 10 mL, 15 mL and 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information TERRITORY TRADE NAME DEVELOPMENT STAGE DISTRIBUTOR Australia Omniscan® for sale | |  | | • View the DATABASE results for 'Omniscan®' (7).
| | | | Further Reading: | Basics:
|
|
News & More:
| |
| |
|  | |  |  |  |
| |
|
Short name: Gd-DTPA, generic name: Gadopentetate dimeglumine, chemical compound: Gadolinium-diethylenetriaminepentaacetic acid
Gadopentetate dimeglumine was introduced in 1981, as the first paramagnetic MRI contrast agent (ionic). The Gd-induced dipole dipole interactions lead to shortening of T1, which results in contrast enhancement on T1 weighted images. The used metal ion Gd3+ ( gadolinium) is toxic, and therefore bound in the renally excreted DTPA chelate, a very stable complex. The Gd-complex also induce susceptibility effects, as a result of the magnetic field gradient between the contrast agent in the blood vessels and the surrounding tissue, that lead to shortening of T2 or T2*.
Following intravenous administration, the compound is distributed rapidly in the ex tracellular space and is eliminated unchanged by glomerular filtration via the kidneys. Up to 6 hours, post injection an average of 83% of the dose is eliminated renal.
See also Magnevist®, Gadolinium and Contrast Agents. | |  | | • View the DATABASE results for 'Gadopentetate Dimeglumine' (5).
| | | | Further Reading: | Basics:
|
|
News & More:
| |
| |
|  | |  |  |
|  | | |
|
| |
 | Look Ups |
| |