Multi Shot Technique
 
When a multi shot technique is applied, each shot will have its own effect on the prepulse, with a scan time increase. Multiple shots allow a shorter IR delay but at the cost of increased scan time.
In multi shot technique (also called mosaic imaging), a group of samples, which are contiguous in k space are acquired in the same sequence repetition. The phase encoding steps or profiles are split into 'shots' (sub-acquisitions). The shot interval is the time between the shots. Usually kept as short as possible. Because the acquisitions are divided into different shots, each shot will have less T1 variation, thereby increasing T1 contrast. Two excitations, each requiring the data for one half of k-space, are the simplest variation of multi shot techniques (e.g. positive versus negative phase encoding). The alternative to this mosaic strategy for multi shot EPI is interleaving. In interleaved sequences, each repetition acquires every nth (n is the number of shots) line in k-space and for the complete raw data set the various repetition data are interlaced.

See also Single Shot Technique.
spacer
MRI Resources 
Movies - Fluorescence - PACS - Universities - Non-English - Quality Advice
 
NC100150 InjectionInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: NC100150, PEG-feron, generic name: Feruglose, preliminary trade name: Clariscan™
NC100150 injection is the code name for an USPIO (ultrasmall superparamagnetic iron oxide) MRI contrast agent under development. Microvessel permeability depends on functional and morphologic characteristics of cancer vessels and on physicochemical properties of the injected contrast medium molecule.
USPIO particles have a favorable pharmacological and tolerance profile and are being tested clinically of the potential for the quantitative characterization of tumor microvasculature and specifically for measures of the microvessel permeability. Iron-based products take advantage of their large molecular size, which prevents diffusion into body tissues. These agents are disposed of by the liver and spleen as particulate matter.
NC100150 Injection (Nycomed Amersham, Amersham Health ) consists of USPIO particles that are composed of single crystals (4- to 7-nm diameter) and stabilized with a carbohydrate polyethylene glycol (PEG) coat. The iron oxide particles have to be suspended in an isotonic glucose solution. The final diameter of an USPIO particle is approximately 20 nm. Blood pool half-life is more than two hours in humans; the particles are taken up by the mononuclear phagocyte system and distributed mainly to the liver and spleen.
NC100150 would compete with the contrast agents Ferumoxytol from AMAG Pharmaceuticals, Inc. and Vasovist™ from EPIX Pharmaceuticals, Inc., but at this time the development of NC100150 Injection/Clariscan™ is discontinued.
spacer

• View the DATABASE results for 'NC100150 Injection' (5).Open this link in a new window


• View the NEWS results for 'NC100150 Injection' (2).Open this link in a new window.
MRI Resources 
Jobs - Online Books - Most Wanted - Universities - Societies - Process Analysis
 
PRinciples of Echo Shifting using a Train of ObservationsInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(PRESTO) PRESTO is a 3 dimensional ultrafast gradient echo sequence that combines the whole brain coverage with T2* weighted imaging. PRESTO is useful for BOLD and perfusion imaging studies. In combination with parallel imaging techniques, PRESTO provides higher temporal resolution and more coverage compared to traditional multi slice imaging. In addition, the sensitivity to susceptibility artifacts and flow phenomena is reduced, compared with EPI techniques, enabling MRI scans throughout the brain including the skull base.

See also T2 Star.
spacer

• View the DATABASE results for 'PRinciples of Echo Shifting using a Train of Observations' (2).Open this link in a new window

 
Further Reading:
  News & More:
Chest MRI Using Multivane-XD, a Novel T2-Weighted Free Breathing MR Sequence
Thursday, 11 July 2019   by www.sciencedirect.co    
T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
Friday, 16 October 2015   by www.ncbi.nlm.nih.gov    
Searchterm 'epi' was also found in the following services: 
spacer
News  (35)  Resources  (6)  Forum  (15)  
 
Point Resolved SpectroscopyInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(PRESS) Point resolved spectroscopy is a multi echo single shot technique to obtain spectral data. PRESS is a 90°-180°-180° (slice selective pulses) sequence. The 90° radio frequency pulse rotates the spins in the yx-plane, followed by the first 180° pulse (spin rotation in the xz-plane) and the second 180° pulse (spin rotation in the xy-plane), which gives the signal.
With the long echo times used in PRESS, there is a better visualization of metabolites with longer relaxation times. Many of the metabolites depicted by stimulated echo technique are not seen on point resolved spectroscopy, but PRESS is less susceptible to motion, diffusion, and quantum effects and has a better SNR than stimulated echo acquisition mode (STEAM).
spacer

• View the DATABASE results for 'Point Resolved Spectroscopy' (3).Open this link in a new window

 
Further Reading:
  Basics:
The Basics of MRI
   by www.cis.rit.edu    
  News & More:
MRI evaluation of fatty liver in day to day practice: Quantitative and qualitative methods
Wednesday, 3 September 2014   by www.sciencedirect.com    
MRI Resources 
Education - Journals - Crystallography - Fluorescence - Non-English - Most Wanted
 
PregnancyMRI Resource Directory:
 - Safety -
 
MRI can be indicated for use in pregnant women if other forms of diagnostic imaging are inadequate or require exposure to ionizing radiation such as X-ray or CT.
As a safety precaution, MR scanning should be avoided in the first three months of pregnancy.
Similar considerations hold for pregnant staff of a magnetic resonance department. An epidemiological study (by Kanal, et al.) concluded that data collected from MRI technologists were negative with respect to any statistically significant elevations in the rates of spontaneous abortion, infertility and premature delivery.
However, also for psychological reasons, it might be a wise precaution that pregnant staff members do not remain in the scan room during actual scanning.
There have been several reports (results could not be reproduced) that static magnetic fields may provoke genetic mutations, changes in growth rate and leukocyte count and other effects. No reports have been published that persons exposed to magnetic fields, including staff at MR departments, have a higher incidence of genetic damage to their children than found in the average population.
This research needs further investigation and for this purpose pregnancy should be considered a relative contraindication for MR spectroscopy and MRI procedures.
Taking into account that clinical MR imaging devices operate at field strengths of between 0.2 and 2.0 T, higher field strengths need more investigation.
mri safety guidance
MRI Safety Guidance
Today, there is no sign that MR can harm the fetus or embryo (MRI is used for fetal MRI - fetography). However, if a MRI examination is ordered, there should be a strict indication for this examination.

See also the related poll result: 'MRI will have replaced 50% of x-ray exams by'
 
Images, Movies, Sliders:
 Normal Fetus  Open this link in a new window
    

Courtesy of  Robert R. Edelman
 Pregnancy and Small Bowel Obstruction  Open this link in a new window
 
spacer

• View the DATABASE results for 'Pregnancy' (5).Open this link in a new window


• View the NEWS results for 'Pregnancy' (1).Open this link in a new window.
 
Further Reading:
  News & More:
Assessment of Female Pelvic Pathologies: A Cross-Sectional Study Among Patients Undergoing Magnetic Resonance Imaging for Pelvic Assessment at the Maternity and Children Hospital, Qassim Region, Saudi Arabia
Saturday, 7 October 2023   by www.cureus.com    
MRI scans more precisely define and detect some abnormalities in unborn babies
Friday, 12 March 2021   by www.eurekalert.org    
Simple MRI method could help predict complications early in pregnancy
Friday, 8 November 2019   by www.radiologybusiness.com    
Many women exposed to MRI 'dye' in early pregnancy
Tuesday, 20 August 2019   by www.upi.com    
3-D MRI predicts pregnancies complicated by fetal growth restriction
Monday, 31 July 2017   by www.sciencedaily.com    
MRI helps predict preterm birth
Tuesday, 15 March 2016   by www.eurekalert.org    
Serious Pregnancy Complication Detected With MRI
Tuesday, 1 December 2009   by health.usnews.com    
MRI Resources 
MRA - Liver Imaging - Crystallography - Intraoperative MRI - Open Directory Project - Developers
 
previous      71 - 75 (of 86)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



New acceleration techniques will :
reduce scan times 
cause artifacts 
increase expenses 
be useful if you have a lot of experience 
doesn't do much 
never heard of 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 3 December 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]