Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'paramagnetic' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'paramagnetic' found in 10 terms [] and 91 definitions []
previous     86 - 90 (of 101)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
Searchterm 'paramagnetic' was also found in the following services: 
spacer
News  (9)  Resources  (5)  Forum  (3)  
 
Myocardial Late Enhancement
 
(LE) Myocardial late enhancement in contrast enhanced cardiac MRI has the ability to precisely delineate myocardial scar associated with coronary artery disease. Viability imaging implies evaluating infarcted myocardium to see whether there is enough viable tissue available for revascularization. The reversal of myocardial dysfunction is particularly relevant in patients with depressed ventricular function because revascularization improves long-term survival. In comparison to SPECT and PET imaging, myocardial late enhancement MRI demonstrates areas of delayed enhancement exactly in correlation with the infarcted region.
Viability on cardiac MRI (CMR) is based on the fact that all infarcts enhance vividly 10-15 minutes after the administration of intravenous paramagnetic contrast agents. This enhancement represents the accumulation of gadolinium in the extracellular space, due to the loss of membrane integrity in the infarcted tissue. This phenomenon of delayed hyperenhancement has been proven to correlate with the actual extent of the infarct.
MRI myocardial late enhancement can quantify the size, location and transmural extent of the infarct. If the transmural extent of the infarct (region of enhancement on MRI) is less than 50% of the wall thickness, there will be improved contractility in that segment following revascularization. In areas of hypokinesia, if there is a rim of "black" or non-infarcted myocardium that is not contracting well, it indicates the presence of hibernating myocardium, which is likely to improve after revascularization of the artery supplying that particular territory.
The total duration of a myocardial late enhancement MR imaging protocol for viability is approximately 30 minutes, including scout images, first-pass images, cine images in two planes, and delayed myocardial enhancement images. In order to assess viable myocardium, the gadolinium contrast agent is injected at a dose of 0.15 to 0.2 mmol/kg. After about 10 minutes, short axis and long axis views (see cardiac axes) of the heart are obtained using an inversion prepared ECG gated gradient echo sequence. The inversion pulse is adjusted to suppress normal myocardium. Areas of nonviable myocardium retain extremely high signal intensity, black areas show normal tissue.

For Ultrasound Imaging (USI) see Myocardial Contrast Echocardiography at Medical-Ultrasound-Imaging.com.
spacer
 
• Related Searches:
    • Cardiovascular Imaging
    • Cardiac Axes
    • Displacement Encoding with Stimulated Echoes
    • Perfusion Imaging
    • Paramagnetic Contrast Agents
 
Further Reading:
  Basics:
A Guide To Cardiac Imaging
   by www.simplyphysics.com    
  News & More:
Prediction of Myocardial Viability by MRI
1999   by circ.ahajournals.org    
Geron Demonstrates hESC-derived cardiomyocytes improve heart function after myocardial infarction
Monday, 27 August 2007   by www.brightsurf.com    
MRI Resources 
Databases - Coils - Homepages - Software - Stent - Mass Spectrometry
 
NC100150 InjectionInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: NC100150, PEG-feron, generic name: Feruglose, preliminary trade name: Clariscan™
NC100150 injection is the code name for an USPIO (ultrasmall superparamagnetic iron oxide) MRI contrast agent under development. Microvessel permeability depends on functional and morphologic characteristics of cancer vessels and on physicochemical properties of the injected contrast medium molecule.
USPIO particles have a favorable pharmacological and tolerance profile and are being tested clinically of the potential for the quantitative characterization of tumor microvasculature and specifically for measures of the microvessel permeability. Iron-based products take advantage of their large molecular size, which prevents diffusion into body tissues. These agents are disposed of by the liver and spleen as particulate matter.
NC100150 Injection (Nycomed Amersham, Amersham Health ) consists of USPIO particles that are composed of single crystals (4- to 7-nm diameter) and stabilized with a carbohydrate polyethylene glycol (PEG) coat. The iron oxide particles have to be suspended in an isotonic glucose solution. The final diameter of an USPIO particle is approximately 20 nm. Blood pool half-life is more than two hours in humans; the particles are taken up by the mononuclear phagocyte system and distributed mainly to the liver and spleen.
NC100150 would compete with the contrast agents Ferumoxytol from AMAG Pharmaceuticals, Inc. and Vasovist™ from EPIX Pharmaceuticals, Inc., but at this time the development of NC100150 Injection/Clariscan™ is discontinued.
spacer

• View the DATABASE results for 'NC100150 Injection' (5).Open this link in a new window


• View the NEWS results for 'NC100150 Injection' (2).Open this link in a new window.
MRI Resources 
NMR - Distributors - Jobs pool - Service and Support - Software - Equipment
 
Necrosis Avid Contrast AgentInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
(NACA) Some porphyrin (e.g. Gadophrin-2) and non-porphyrin (e.g. CEIII-60) paramagnetic chelates are able to specifically accumulate in nonviable tissues and can be applied as a MRI contrast agent for acute myocardial infarction and therapeutic necrosis. This function of necrosis avid contrast agents is a unique pathological targetability. These agents can also be exploited for multipurpose applications, because NACAs also bear other common properties including early systemic distribution, albumin binding, hepatocellular uptake and renal elimination.

See also the related poll result: 'The development of contrast agents in MRI is'
spacer

• View the DATABASE results for 'Necrosis Avid Contrast Agent' (9).Open this link in a new window


• View the NEWS results for 'Necrosis Avid Contrast Agent' (1).Open this link in a new window.
 
Further Reading:
  Basics:
Tumor-targeted MR Contrast Agents: Hype or Future Hope?
November 2004   by radiology.rsnajnls.org    
  News & More:
Rockland Technimed: Tissue Viability Imaging
Saturday, 15 December 2007   by www.onemedplace.com    
Searchterm 'paramagnetic' was also found in the following services: 
spacer
News  (9)  Resources  (5)  Forum  (3)  
 
Omniscan®InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Omniscan® is a nonionic chelate complex with low osmolality used as a paramagnetic MRI contrast agent. The efficacy of Omniscan® is similar to that of Gd-DTPA. Omniscan® is given intravenously to enhance images of intracranial and spinal lesions where there is abnormal vascularity or an abnormal blood brain barrier. The complex does not cross an intact blood brain barrier so Omniscan® only accumulates in lesions such as neoplasm's and abscesses.

WARNING: NEPHROGENIC SYSTEMIC FIBROSIS Gadolinium-based contrast agents increase the risk for nephrogenic systemic fibrosis (NSF) in patients with acute or chronic severe renal insufficiency (glomerular filtration rate less than 30 mL/min/1.73m2), or acute renal insufficiency of any severity due to the hepato-renal syndrome or in the perioperative liver transplantation period.

See also Gadodiamide, and Classifications, Characteristics, etc.
Drug Information and Specification
NAME OF COMPOUND
Gadodiamide, Gd-DTPA-BMA
CENTRAL MOIETY
Gd2+
CONTRAST EFFECT
T1, Predominantly positive enhancement
r1=3.9, r2=4.3, B0=1.0T
PHARMACOKINETIC
Intravascular, extracellular, renal excretion
798 mosm/kgH2O
CONCENTRATION
287 mg/mL,0.5 mol/L
DOSAGE
0.1-0.2 mmol/kg / 0.2-0.4 ml/kg
PREPARATION
Finished product
INDICATION
Neuro/whole body
DEVELOPMENT STAGE
For sale
DISTRIBUTOR
See below
PRESENTATION
Vials of 10 mL, 15 mL and 20 mL
DO NOT RELY ON THE INFORMATION PROVIDED HERE, THEY ARE
NOT A SUBSTITUTE FOR THE ACCOMPANYING PACKAGE INSERT!
Distribution Information
TERRITORY
TRADE NAME
DEVELOPMENT
STAGE
DISTRIBUTOR
USA
Omniscan®
for sale
EU
Omniscan®
suspended
Australia
Omniscan®
for sale
spacer

• View the DATABASE results for 'Omniscan®' (7).Open this link in a new window

 
Further Reading:
  Basics:
Important Drug Warning for Gadolinium-Based Contrast Agents
Wednesday, 12 September 2007   by www.ismrm.org    
Omniscan Pharmacokinetics
  News & More:
Gadolinium-containing contrast agents: removal of Omniscan and iv Magnevist, restrictions to the use of other linear agents
Friday, 5 January 2018   by www.gov.uk    
Spurious Hypocalcemia After Omniscan- or OptiMARK-Enhanced Magnetic Resonance Imaging: An Algorithm for Minimizing a False-Positive Laboratory Value
October 2004   by www.findarticles.com    
MRI Resources 
Developers - Safety pool - Safety Training - Service and Support - Online Books - Cardiovascular Imaging
 
Oxygen Mapping
 
The activation of the brain is mirrored in the local changes in metabolism and hemodynamics (brit. haemodynamics). By using heavily T2 weighted scans activated brain areas show an increase in signal intensity as oxyhaemoglobin (brit. oxyhaemoglobin) is diamagnetic and deoxyhemoglobin (brit. deoxyhaemoglobin) is paramagnetic. Oxygen mapping will benefit from high field strength.

See also Blood Oxygenation Level Dependent Contrast, Haemoglobin, Perfusion Imaging, Diamagnetism, Paramagnetism.
spacer

• View the DATABASE results for 'Oxygen Mapping' (2).Open this link in a new window

 
Further Reading:
  News & More:
Potential and Limitations of Oxygen-17 MR Perfusion Measurements
Monday, 1 March 2004   by www.case.edu    
Gold Acupuncture Needle MRI Pain Discovery
Friday, 3 January 2014   by www.healthcmi.com    
Brain-imaging technique could offer invaluable prognostic data
Thursday, 16 February 2012   by www.theengineer.co.uk    
MRI Resources 
Guidance - Databases - RIS - Image Quality - Chemistry - General
 
previous      86 - 90 (of 101)     next
Result Pages : [1 2]  [3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ... ]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



How AI will impact MRI :
only diagnostics 
saving time 
reducing cost 
makes planning obsolete 
reduce human knowledge 
not at all 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]