Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'perfusion' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'perfusion' found in 2 terms [] and 33 definitions []
previous     26 - 30 (of 35)     next
Result Pages : [1]  [2 3 4 5 6 7]
Searchterm 'perfusion' was also found in the following services: 
spacer
News  (13)  Resources  (7)  Forum  (5)  
 
Lung ImagingMRI Resource Directory:
 - Lung Imaging -
 
Lung imaging is furthermore a challenge in MRI because of the predominance of air within the lungs and associated susceptibility issues as well as low signal to noise of the inflated lung parenchyma. Cardiac and respiratory triggered or breath hold sequences allow diagnostic imaging, however a comparable image quality with computed tomography is still difficult to achieve.
Assumptions for lung MRI:
Low signal to noise ratio of the inherently low lung proton density.
Cardiac and respiratory motion artifacts.
Magnetic susceptibility effects of large magnetic field gradients.
Very short transverse relaxation times and significant diffusion yielding short T2 (30-70 msec), short T2* (1-3 msec), and additional long T1 relaxation times (1300-1500 msec).
The extreme short T2 values are responsible for a fast signal decay during a single shot readout, resulting in blurring.

The current trends in MRI are the use of new imaging technologies and increasingly powerful magnetic fields. Among these technologies are parallel imaging techniques as well as ventilation agents like hyperpolarized helium for the use as an inert inhalational contrast agent to study lung ventilation properties. With hyperpolarized gases clear images of the lungs can be obtained without using a large magnetic field (see also back projection imaging). Single shot sequences (e.g. TSE or Half Fourier Acquisition Single Shot Turbo Spin Echo HASTE) used in lung MR imaging benefits from parallel imaging techniques due to reduced relaxation time effects during the echo train and therefore reduced image blurring as well as reduced motion artifacts.
In the future, more effective contrast agents may provide an alternative solution to the need for high field MRI. Dynamic contrast enhanced MRI perfusion has demonstrated a potential in the diagnosis of pulmonary embolism or to characterize lung cancer and mediastinal tumors. 3D contrast enhanced magnetic resonance angiography of the thoracic vessel.

See also the related poll result: 'MRI will have replaced 50% of x-ray exams by'
 
Images, Movies, Sliders:
 Anatomic Imaging of the Lungs  Open this link in a new window
      

Courtesy of  Robert R. Edelman
 Normal Lung Gd Perfusion MRI  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 MRI Thorax Basal Plane  Open this link in a new window
 
Radiology-tip.comradLung Scintigraphy
spacer
 
• Related Searches:
    • Single Shot Technique
    • Contrast Enhanced MRI
    • Cardiac Gating
    • Parallel Imaging Technique
    • Cardiovascular Imaging
 
Further Reading:
  Basics:
A safer approach for diagnostic medical imaging
Monday, 29 September 2014   by www.eurekalert.org    
Parallel Lung Imaging(.pdf)
  News & More:
Chest MRI a viable alternative to chest CT in COVID-19 pneumonia follow-up
Monday, 21 September 2020   by www.healthimaging.com    
CT Imaging Features of 2019 Novel Corona virus (2019-nCoV)
Tuesday, 4 February 2020   by pubs.rsna.org    
Polarean Imaging Phase III Trial Results Point to Potential Improvements in Lung Imaging
Wednesday, 29 January 2020   by www.diagnosticimaging.com    
Low Power MRI Helps Image Lungs, Brings Costs Down
Thursday, 10 October 2019   by www.medgadget.com    
Chest MRI Using Multivane-XD, a Novel T2-Weighted Free Breathing MR Sequence
Thursday, 11 July 2019   by www.sciencedirect.co    
Researchers Review Importance of Non-Invasive Imaging in Diagnosis and Management of PAH
Wednesday, 11 March 2015   by lungdiseasenews.com    
New MRI Approach Reveals Bronchiectasis' Key Features Within the Lung
Thursday, 13 November 2014   by lungdiseasenews.com    
MRI techniques improve pulmonary embolism detection
Monday, 19 March 2012   by medicalxpress.com    
  News & More:
Partnership with VIDA to streamline adoption of advanced MRI of the lungs
Monday, 11 September 2023   by www.itnonline.com    
MRI Resources 
Spine MRI - Lung Imaging - Fluorescence - Homepages - Stent - Equipment
 
MS-325Forum -
related threadsInfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
MS-325 is the formerly code name of gadofosveset trisodium (new trade name Vasovist). MS-325 belongs to a new class of blood pool agents for magnetic resonance angiography (MRA) to diagnose vascular disease. Gadofosveset trisodium has ten times the signal-enhancing power of existing contrast agents as well as prolonged retention in the blood. This enables the rapid acquisition of high resolution MRA's using standard MRI machines.
Gadofosveset trisodium, which is gadolinium-based, stays in the blood stream as a result of transient binding to albumin. Albumin binding offers an additional benefit beyond localization in the blood pool. The contrast agent begins to spin much more slowly, at the rate albumin spins, causing a relaxivity gain that produces a substantially brighter signal than would be possible with freely circulating gadolinium. MS-325 is an intravascular contrast agent intended for use in MRI as an aid in diagnosing aortoiliac occlusive disease in patients with known or suspected peripheral vascular disease (PVD) or abdominal aortic aneurysm (AAA).
Currently clinical trials completed for peripheral vascular disease and coronary artery disease. Additional trials are also being conducted to evaluate MS-325 as an aid in diagnosing breast cancer and suggested that it might be feasible to combine the use of MS-325, injected during peak stress, with delayed high-resolution imaging to identify myocardial perfusion defects.
Vasovist (MS-325) would compete with the contrast agents Ferumoxytol (Code 7228) from AMAG Pharmaceuticals, Inc. and NC100150 Injection from Nycomed Amersham, but their further development is uncertain.
Partners in development: EPIX Pharmaceuticals, Inc., Mallinckrodt Inc., and Bayer Schering Pharma AG. Bayer Schering Pharma has the worldwide marketing rights for the product.
Formerly known under the Mallinckrodt trademark name, AngioMARK®.

See also Classifications, Characteristics, etc.
spacer

• View the DATABASE results for 'MS-325' (4).Open this link in a new window


• View the NEWS results for 'MS-325' (10).Open this link in a new window.
 
Further Reading:
  News & More:
EPIX Medical's new multimedia Web site features AngioMARK images in 3D
Friday, 5 March 1999
MRI technology combined with contrast agent optimizes diagnosis of cardiovascular disease
1999
MRI Resources 
Devices - RIS - Stent - Fluorescence - Open Directory Project - Developers
 
Oxygen Mapping
 
The activation of the brain is mirrored in the local changes in metabolism and hemodynamics (brit. haemodynamics). By using heavily T2 weighted scans activated brain areas show an increase in signal intensity as oxyhaemoglobin (brit. oxyhaemoglobin) is diamagnetic and deoxyhemoglobin (brit. deoxyhaemoglobin) is paramagnetic. Oxygen mapping will benefit from high field strength.

See also Blood Oxygenation Level Dependent Contrast, Haemoglobin, Perfusion Imaging, Diamagnetism, Paramagnetism.
spacer

• View the DATABASE results for 'Oxygen Mapping' (2).Open this link in a new window

 
Further Reading:
  News & More:
Potential and Limitations of Oxygen-17 MR Perfusion Measurements
Monday, 1 March 2004   by www.case.edu    
Gold Acupuncture Needle MRI Pain Discovery
Friday, 3 January 2014   by www.healthcmi.com    
Brain-imaging technique could offer invaluable prognostic data
Thursday, 16 February 2012   by www.theengineer.co.uk    
Searchterm 'perfusion' was also found in the following services: 
spacer
News  (13)  Resources  (7)  Forum  (5)  
 
P792InfoSheet: - Contrast Agents - 
Intro, Overview, 
Characteristics, 
Types of, 
etc.MRI Resource Directory:
 - Contrast Agents -
 
Short name: P792, generic name: Gadomeritol, preliminary trade name: Vistarem™, central moiety: Gd
A macromolecular Gd-DOTA derivate under development as a MRI blood pool agent with rapid clearance. Phase II of the clinical trials on P792 (Guerbet SA) will make it possible to validate the performance of this agent in the fields of angiography, myocardial perfusion and tumor characterization.
spacer

• View the DATABASE results for 'P792' (2).Open this link in a new window


• View the NEWS results for 'P792' (1).Open this link in a new window.
 
Further Reading:
  News & More:
The Toolbox Indirectly, tissue is the issue
MRI Resources 
Spectroscopy pool - Process Analysis - Jobs - Musculoskeletal and Joint MRI - Education pool - MRI Accidents
 
PRinciples of Echo Shifting using a Train of ObservationsInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
(PRESTO) PRESTO is a 3 dimensional ultrafast gradient echo sequence that combines the whole brain coverage with T2* weighted imaging. PRESTO is useful for BOLD and perfusion imaging studies. In combination with parallel imaging techniques, PRESTO provides higher temporal resolution and more coverage compared to traditional multi slice imaging. In addition, the sensitivity to susceptibility artifacts and flow phenomena is reduced, compared with EPI techniques, enabling MRI scans throughout the brain including the skull base.

See also T2 Star.
spacer

• View the DATABASE results for 'PRinciples of Echo Shifting using a Train of Observations' (2).Open this link in a new window

 
Further Reading:
  News & More:
Chest MRI Using Multivane-XD, a Novel T2-Weighted Free Breathing MR Sequence
Thursday, 11 July 2019   by www.sciencedirect.co    
T2-Weighted Liver MRI Using the MultiVane Technique at 3T: Comparison with Conventional T2-Weighted MRI
Friday, 16 October 2015   by www.ncbi.nlm.nih.gov    
MRI Resources 
Anatomy - Education - - Mass Spectrometry - Brain MRI - Collections
 
previous      26 - 30 (of 35)     next
Result Pages : [1]  [2 3 4 5 6 7]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]