meike carr

Mon. 23 Oct.17,
15:48

[Start of:
'Dialysis pt and Artifacts'
0 Reply]


 
  Category: 
General

 
Dialysis pt and Artifacts
We are having an artifact or loss of signal when we do some dialysis patients spine work. Both of our machines are GE 1.5 and a 3t. It does not happen on all dialysis patients only a few but the images will come out completely dark. We typically do not have any issues with our spine imaging. Has anyone else had this issue or heard of this? Any suggestions on how to fix, it is worse on the 3t of course.
Reply to this thread
(login or register first)
Arnold Somereville

Sun. 23 Apr.17,
18:06

[Start of:
'GE 8 channel Body Coil Artifact'
2 Replies]


 
  Category: 
Artifacts

 
GE 8 channel Body Coil Artifact
Have a GE 1.5T HDxt. Problem: experiencing symmetric artifacts in abdominal images. Artifact seen in most anterior images: Some are rectangular in appearance, another reminds me of a plastic knife. All patients are changed in gowns/pants prior to entry into MRI suite. The body coil in question has been changed 3 times but the artifact remains. I suspect this is a hardware reconstruction issue, however, the engineer thinks it is operator error. I have run this sequence with and without options. This is an SSFSE, breath hold sequence. Has anyone encountered this issue?
 
 
MRI Abdomen 8 channel body coil


 View the whole threadReply to this thread
(login or register first)
Jon Selby

Tue. 26 Apr.16,
07:57

[Start of:
'Susceptibility artifact query'
0 Reply]


 
  Category: 
General

 
Susceptibility artifact query
As an MRI 'newbie' would someone be willing to help me with a question on magnetic susceptibility. If you have two metal implants of the same external geometrical form but one of these is hollow, would you you get the same size artifact? I'm basically wondering whether a metallic implant has a finite sphere of influence or whether it is compounded by the volume of material. Much appreciated, Jon
Reply to this thread
(login or register first)
Edmund Kwok

Tue. 20 Oct.15,
20:34

[Start of:
'Artifact in Abdomen LAVA'
0 Reply]


 
  Category: 
Artifacts

 
Artifact in Abdomen LAVA
This artifact appears on every slice of an abdomen LAVA scan, and it looks like puzzle pieces. The artifact was gone in a re-scan using similar parameters. Does any one has an idea what might have caused it? Thanks.
Reply to this thread
(login or register first)
luna xu

Fri. 5 Jun.15,
14:22

[Start of:
'is this kind of zebra artifact?'
1 Reply]


 
  Category: 
Artifacts

 
is this kind of zebra artifact?
Always existed artifact made us crazy, is this a kind of zebra artifact or something? the line are in the phase encoding direction, really confusing.
 
 
artifact


 View the whole threadReply to this thread
(login or register first)

Result Pages : [1] 2 3 4 5 6 7 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]