Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 

Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 




 
MRI Forum
'Echo'
SEARCH FORUM FOR   
 
Result: Searchterm 'Echo' found in 43 messages
Result Pages: 1 2 3 4 5 6 7 8 [9] 
More Results: Database  (305)  News Service  (7)  Resources  (10)  
Forum Overview
 bottom
john devonport

Wed. 14 Jul.04,
03:14

[Start of:
'Endorem Resovist'
1 Reply]


 
  Category: 
Contrast Agents

 
Endorem Resovist
We use Endorem for liver imaging. We will change to Resovist. Does anyone have experience with this new contrast agent? By now, we use post contrast a T2 weighted sequence with an echo time of 60 (1.5 T Intera). Do we have to pay attention to something, what’s different to Endorem?
 View the whole threadReply to this thread
(login or register first)
Tom Bellini

Mon. 14 Jun.04,
01:57

[Reply (1 of 3) to:
'Black Blood MRA'
started by: 'ranran zhao'
on Sun. 6 Jun.04]


 
  Category: 
Applications and Examinations

 
Black Blood MRA
The black blood effect is a natural high contrast between blood and myocardium caused by the flow void of blood. Black blood techniques are for example used to demonstrate fatty infiltration of the right ventricular wall with right ventricular dysplasia. Black blood MRA is usual based on fast spin echo or inversion recovery sequences and seldom used as cine imaging. The advantage of this type of sequence consists of being less sensitive to respiratory and cardiac motion. Bright blood cine imaging is the standard method, but there are manufacturer with different techniques, e.g. Toshiba has a black blood cine technique.
 View the whole thread
Schmidt Marga

Sat. 17 Apr.04,
20:41

[Reply (1 of 2) to:
'Moire fringing'
started by: 'Kelly Wimpey'
on Tue. 6 Apr.04]


 
  Category: 
Artifacts

 
Moire fringing
Moire fringes are typical for gradient echo sequences, especially balanced sequences like for example true fisp, bFFE. The reasons are interferences and field inhomogeneities. High order shimming (volume shimming), a more suitable coil, a smaller bandwidth, and scanning not in the edges of the magnetic field will avoid or reduce this artifact. Also parallel imaging techniques can have a positive influence. If this artifact appears, also by using other sequences, a new field adjustment can be necessary (service).
Hope this will help.
 View the whole thread

Result Pages : 1 2 3 4 5 6 7 8 [9] 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]