Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 

MRI is trending to low field magnets :
reduced costs will lead to this change 
AI will close the gap to high field 
only in remote areas 
is only temporary 
never 




 
MRI Forum
'Magnet'
SEARCH FORUM FOR   
 
Result: Searchterm 'Magnet' found in 87 messages
Result Pages: 1 2 3 4 5 6 7 8 [9] 10 11 12 13 14 15 16 17 18 
More Results: Database  (669)  News Service  (897)  Resources  (213)  
Forum Overview
 bottom
Hussein AlSayiegh

Sat. 21 May.11,
15:45

[Start of:
'mr scanner next to physio therapy clinic'
1 Reply]


 
  Category: 
Site Planning and Specifications

 
mr scanner next to physio therapy clinic
Hi,

A facillity plans to build a physio therapy clinic next to MRI suite. They have two GE MRI's. A 1.5T and .7T open magnet. Any advice?

thanks in advance
 View the whole threadReply to this thread
(login or register first)
Elise Gough

Mon. 7 Mar.11,
16:54

[Reply (7 of 8) to:
'6-1.5T MAGNETS, DIFFERING GRADIENTS'
started by: 'Elise Gough'
on Wed. 23 Feb.11]


 
  Category: 
Applications and Examinations

 
6-1.5T MAGNETS, DIFFERING GRADIENTS
Thank you for your logical advice. Just spoke with GE apps. "No amount of messing with MR parameters can compensate for weak gradients. Increased gradient strength=decreased echo spacing=less blurring". Coincidently, my DO just emailed me asking what the gradient strength is on the magnet the RADs are complaining about.Just MAYBE they'll upgrade it. I need to visit our sites.The only way I have to check other sites' parameters is importing exams from PACS to my modality console. Tedious, but telling. Again, thankyou for all the help.
 
 

Elise Gough RT(R)(CT)(MR)
 View the whole thread
Steven Ford

Mon. 7 Mar.11,
16:07

[Reply (6 of 8) to:
'6-1.5T MAGNETS, DIFFERING GRADIENTS'
started by: 'Elise Gough'
on Wed. 23 Feb.11]


 
  Category: 
Applications and Examinations

 
6-1.5T MAGNETS, DIFFERING GRADIENTS
We maintain a lot of magnets. The leading cause of image quality problems is applications related. Nobody can possibly know all the nuances of pulse sequences by various vendors, software levels, etc. I've heard many times that a certain machine is no good, when in fact the sequences are inefficiently set up. Look there first.

Usually the techs welcome good training. If they don't want to be trained, then you have a problem, but it sounds like this issue is caused by other factors.

If there are differences in baseline quality between the machines, then compensate for that by other means. Signal starvation is easily remedied; keep the quality as consistent as you can and let time be the variable, if it comes down to that.




 View the whole thread
Elise Gough

Mon. 7 Mar.11,
15:56

[Reply (5 of 8) to:
'6-1.5T MAGNETS, DIFFERING GRADIENTS'
started by: 'Elise Gough'
on Wed. 23 Feb.11]


 
  Category: 
Applications and Examinations

 
6-1.5T MAGNETS, DIFFERING GRADIENTS
Thanks so much for the input. NOBODY in my group seems to have a handle on why images vary in quality from 8 different magnets. I'm being pressed to take position of imaging specialist and thru my own research we have gradient strengths from 50 slew rate up to 120. Radiologists complain neuro stinks on the 50 slew rate 1.5T magnet and it is the most pounded on magnet in our group doing hospital inpatients. So many variables including tech expertise.
 
 

Elise Gough RT(R)(CT)(MR)
 View the whole thread
Renate Semrau

Mon. 7 Mar.11,
15:11

[Reply (3 of 8) to:
'6-1.5T MAGNETS, DIFFERING GRADIENTS'
started by: 'Elise Gough'
on Wed. 23 Feb.11]


 
  Category: 
Applications and Examinations

 
6-1.5T MAGNETS, DIFFERING GRADIENTS
Slew rate, rise time and/or duty cycle are specific parameters to describe the performance of the gradient amplifier. Amplifiers with higher performance allow a faster slew rate (shorter rise time). Stronger gradients allow to reduce echo time, increase the bandwidth and/or use a smaller FOV by influencing the SNR. To use same parameters on magnets with different gradient performance may not be recommended, or you have to adjust all parameters to the level of your magnet with the poorest performance.
 View the whole thread

Result Pages : 1 2 3 4 5 6 7 8 [9] 10 11 12 13 14 15 16 17 18 
 top
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Look
      Ups






MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 21 November 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]