Magnetic
Resonance -
Technology
Information
Portal |
Welcome to MRI Technology• |
|
|
| Info Sheets |
| | | | | | | | | | | | | | | | | | | | | | | | |
| Out- side |
| | | | |
|
| | | | | |
Result: Searchterm 'Slice'
found in 37 messages |
Result Pages: 1 2 [3] 4 5 6 7 8 |
More Results: Database (177) News Service (6) Resources (5) |
|
Martin Rosellen
Wed. 19 Oct.16, 15:30
[Start of: 'k space explanation' 2 Replies]
Category:
General |
k space explanation |
dear all,
I am trying to get a feel for what k-space is. So far I have not got an explanation that I understand. My idea to picture the frequencies that get emmitted from a slice as follows: - We have a box filled with still waterrn - a set of objects get dropped into the water simultaneously - every object emmits waves that are specific to its shape. To fill k space, what is measured and how? All I know is that the sampling frequency stays the same. Sorry for the ugly formatting. Did not find help on that. Thanks Martin
|
| View the whole thread | Reply to this thread (login or register first) | |
Haider Ali
Thu. 15 Sep.16, 02:26
[Start of: 'Toshiba Vantage Titan 3T' 0 Reply]
Category:
Equipment |
Toshiba Vantage Titan 3T |
While planning vertebral discs for axial cuts is there any way to align the slices perpendicularly on coronal plane? Currently I have to manually align them on the vertebral column which is tedious and sometimes erroneous.
I have worked on Siemens Avanto and there is option to select the slice to align perpendicular so that I only have to pay attention to one plane while in Toshiba the task is a bit more complicated. Though there is an option of aligning all slices perpendicularly but it does not work or may be I am doing something wrong.
|
| | Reply to this thread (login or register first) | |
Marlee Smith
Sat. 23 Jan.16, 00:45
[Start of: 'Brain MRI Help' 0 Reply]
Category:
General |
Brain MRI Help |
Can someone please help me interpret this horizontal MRI T2 slice? The images are of just behind my eyes. I don't think those black dots are meant to be there... I know that foramen make a black dot but I don't think that there are any foramen where the dots are.
|
| | Reply to this thread (login or register first) | |
Edmund Kwok
Tue. 20 Oct.15, 20:34
[Start of: 'Artifact in Abdomen LAVA' 0 Reply]
Category:
Artifacts |
Artifact in Abdomen LAVA |
This artifact appears on every slice of an abdomen LAVA scan, and it looks like puzzle pieces. The artifact was gone in a re-scan using similar parameters. Does any one has an idea what might have caused it? Thanks.
|
| | Reply to this thread (login or register first) | |
dimitris priovolos
Sat. 21 Dec.13, 10:14
[Reply (1 of 2) to: 'mr urography' started by: 'elena giovanelli' on Thu. 24 Oct.13]
Category:
Applications and Examinations |
mr urography |
I think it's better to plan both ureters, put the pack of slices exactly coronal on an axial abdomen slice including both kidneys, take care on a sagital slice to give an angle parallel to spine but including the bladder and the space behind it, use foldover direction (siemens) or Rfov 1 (GE), fov 400-450, sl thick 0.80-1mm, open the 3d slice pack as much as needed, use navigator-pace (siemens) or triggering (GE).
A preparation of diet is needed some times, additional sequences (haste, fiesta, vibe+iv or lava+iv contr) are necessary.
|
| View the whole thread | |
| |
| Result Pages : 1 2 [3] 4 5 6 7 8 | |
|
| |
| Look Ups |
| |
|
MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies. | | [last update: 2024-02-26 03:41:00] |
|
|