Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'DWI' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'DWI' found in 1 term [] and 40 definitions []
previous     26 - 30 (of 41)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
Searchterm 'DWI' was also found in the following services: 
spacer
News  (47)  Resources  (15)  Forum  (27)  
 
DixonInfoSheet: - Sequences - 
Intro, 
Overview, 
Types of, 
etc.
 
The Dixon technique is a MRI method used for fat suppression and/or fat quantification. The difference in magnetic resonance frequencies between fat and water-bound protons allows the separation of water and fat images based on the chemical shift effect.
This imaging technique is named after Dixon, who published in 1984 the basic idea to use phase differences to calculate water and fat components in postprocessing. Dixon's method relies on acquiring an image when fat and water are 'in phase', and another in 'opposed phase' (out of phase). These images are then added together to get water-only images, and subtracted to get fat-only images. Therefore, this sequence type can deliver up to 4 contrasts in one measurement: in phase, opposed phase, water and fat images. An additional benefit of Dixon imaging is that source images and fat images are also available to the diagnosing physician.
The original two point Dixon sequence (number of points means the number of images acquired at different TE) had limited possibilities to optimize the echo time, spatial resolution, slice thickness, and scan time; but Dixon based fat suppression can be very effective in areas of high magnetic susceptibility, where other techniques fail. This insensitivity to magnetic field inhomogeneity and the possibility of direct image-based water and fat quantification have currently generated high research interests and improvements to the basic method (three point Dixon).
The combination of Dixon with gradient echo sequences allows for example liver imaging with 4 image types in one breath hold. With Dixon TSE/FSE an excellent fat suppression with high resolution can be achieved, particularly useful in imaging of the extremities.
For low bandwidth imaging, chemical shift correction of fat images can be made before recombination with water images to produce images free of chemical shift displacement artifacts. The need to acquire more echoes lengthens the minimum scan time, but the lack of fat saturation pulses extends the maximum slice coverage resulting in comparable scan time.
spacer
 
Further Reading:
  Basics:
Separation of fat and water signal in magnetic resonanace imaging
2011   by www.diva-portal.org    
Direct Water and Fat Determination in Two-Point Dixon Imaging
April 2013   by scholarship.rice.edu    
MRI evaluation of fatty liver in day to day practice: Quantitative and qualitative methods
Wednesday, 3 September 2014   by www.sciencedirect.com    
Measurement of Fat/Water Ratios in Rat Liver Using 3DThree-Point Dixon MRI
2004   by www.civm.duhs.duke.edu    
  News & More:
The utility of texture analysis of kidney MRI for evaluating renal dysfunction with multiclass classification model
Tuesday, 30 August 2022   by www.nature.com    
Liver Imaging Today
Friday, 1 February 2013   by www.healthcare.siemens.it    
mDIXON being developed to simplify and accelerate liver MRI
September 2010   by incenter.medical.philips.com    
MRI Resources 
Education pool - MRA - MRI Training Courses - Anatomy - Artifacts - Cochlear Implant
 
Echelon™ 1.5TInfoSheet: - Devices -
Intro, 
Types of Magnets, 
Overview, 
etc.
 
www.hitachimed.com/contentindex.asp?ID=971 From Hitachi Medical Systems America Inc.;
Hitachi expanded its portfolio with the Echelon™ 1.5T. The MRI scanner combines a compact magnet and a scalable 8-channel RF system with high-performance gradients and slew rate to select short echo times, small field of views, high matrices and thin slices. Standard features of the Echelon MRI system include higher-order active shim, RAPID (parallel imaging for use on brain MRI, body, cardiovascular imaging, and orthopedic coils), multiple coil ports, and an advanced reconstruction engine.
Device Information and Specification
CLINICAL APPLICATION
Whole body
CONFIGURATION
Short bore
Head, body coil, spine, breast, knee, shoulder, vascular multiple array coils.
SYNCHRONIZATION
Cardiac gating, ECG/peripheral, respiratory gating
PULSE SEQUENCES
SE, IR, FSE, FIR, GE, SG, BASG, PBSG, PCIR, DWI, Radial, Angiography: TOF, FLUTE (Fluoro-triggered bolus MRA), Time-resolved MRA
IMAGING MODES
Single, multislice, volume study
PIXEL INTENSITY
Level Range: -2,000 to +4,000
Sub millimeter
POWER REQUIREMENTS
208/220/240 V, single phase
CRYOGEN USE
Low cryogen boil-off
STRENGTH
30 mT/m
150 T/m/sec
Higher-order active shim
spacer

• View the DATABASE results for 'Echelon™ 1.5T' (2).Open this link in a new window


• View the NEWS results for 'Echelon™ 1.5T' (3).Open this link in a new window.
 
Further Reading:
  Basics:
Echelon 1.5T
   by www.hitachimed.com    
MRI Resources 
MRI Technician and Technologist Schools - MRI Reimbursement - MRI Technician and Technologist Jobs - Breast Implant - MRI Technician and Technologist Career - Raman Spectroscopy
 
GE LunarMRI Resource Directory:
 - Manufacturers -
 
www.gehealthcare.com [This entry is marked for removal.]

General Electric (GE) agreed to buy diagnostic systems maker Lunar Corp. for $150m. in March 2000. In 2004/05 it seems that the integration process into GE Healthcare has been completed. (GE Medical Systems and Amersham announced in April 2004 the completion of a share exchange acquisition of Amersham Health by GE. The result of this acquisition is the new GE Healthcare, based in the UK, totally owned by General Electric (GE).

The U.S.-based company developed bone densitometers and scanning machines that measure bone density as a way of diagnosing osteoporosis and other metabolic bone diseases. GE Lunar marketed these products worldwide.
GE Lunar announced a distribution agreement with MagneVu for domestic sales of the MagneVu 1000, a portable MRI device for orthopedic use, under the trade name Applause™.
GE Lunar was the exclusive U.S. distributor of MR-devices manufactured by Esaote S.p.A. These compact in-office MRI™ machines are designed to fit all practice sizes in orthopedic imaging and complete the range of diagnostic imaging systems.
spacer

• View the DATABASE results for 'GE Lunar' (2).Open this link in a new window

 
Further Reading:
  News & More:
Portable MR system aids diagnosis of rheumatic diseases
Sunday, 12 January 2003   by www.diagnosticimaging.com    
Searchterm 'DWI' was also found in the following services: 
spacer
News  (47)  Resources  (15)  Forum  (27)  
 
Hitachi Medical Systems America Inc.(USA)/Hitachi Medical Corp.(Tokyo)MRI Resource Directory:
 - Manufacturers -
 
www.hitachimed.com [This entry is marked for removal.]

Hitachi Medical Systems America, Inc. (HMSA), was a major provider of magnetic resonance imaging systems in the United States. Hitachi had more than 2300 installed permanent magnet MR imaging systems worldwide. As a full-line supplier of medical imaging equipment in Japan, Hitachi Medical Corporation (HMC) founded HMSA to provide a direct link to the U.S. marketplace. Altaire™ , the open MR system from Hitachi, extends the family of open MRI products.

In December 2019 Japan's Fujifilm announced the acquisition of Hitachi's diagnostic imaging business for 179 billion yen ($1.63 billion). This includes Hitachi’s CT, MRI, X-ray, and ultrasound imaging operations, also its electronic health record business. Fujifilm expects the deal to close in July 2020 subject to regulatory clearances.

MRI Scanners:

spacer
 
Further Reading:
  News & More:
RSNA update on new MRI technology(.pdf)
February 2006   by www.magnet-mri.org    
Fujifilm to Acquire Hitachi's Diagnostic Imaging-related Business to Accelerate Growth of Its Healthcare Business
Wednesday, 18 December 2019   by www.fujifilm.com    
MRI Resources 
IR - Stent - Safety Training - Software - MRCP - DICOM
 
Image Quality
 
The quality of magnetic resonance imaging is particularly dependent on image resolution (matrix, field of view, slice thickness), contrast (TE, TR), signal to noise ratio (bandwidth, signal averaging) and lack of artifacts. These MRI parameters are affected by the field homogeneity, the field strength, the coil, the pulse sequence type and imaging techniques like parallel imaging.

See also Image Contrast Characteristics.
spacer

• View the DATABASE results for 'Image Quality' (42).Open this link in a new window


• View the NEWS results for 'Image Quality' (4).Open this link in a new window.
 
Further Reading:
  Basics:
Image Characteristics and Quality
   by www.sprawls.org    
  News & More:
Impact of Magnetic Field Inhomogeneity on the Quality of Magnetic Resonance Images and Compensation Techniques: A Review
Saturday, 1 October 2022   by www.dovepress.com    
Researchers design 'intelligent' metamaterial to make MRIs affordable and accessible
Tuesday, 5 November 2019   by phys.org    
Patient movement during MRI: Additional points to ponder
Tuesday, 5 January 2016   by www.healthimaging.com    
Novel Imaging Technique Improves Prostate Cancer Detection
Tuesday, 6 January 2015   by health.ucsd.edu    
MRI Resources 
PACS - Shielding - IR - MRI Training Courses - MRI Technician and Technologist Career - Implant and Prosthesis pool
 
previous      26 - 30 (of 41)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Personalized protocols (age, gender, body habitus, etc.) lead to :
more automated planning 
improved patient comfort 
better diagnostics 
optimized image quality 
nothing 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 27 April 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]